P
Pingxiang Daier Separation TechSep 21, 20263 min read

Engineering Evaluation Case: A Caustic Sour-Gas Scrubber Removes H₂S but Carbonyl Sulfide and CS₂ Remain

When a caustic packed scrubber removes H₂S but total sulfur remains high, identify COS, CS₂, mercaptans, and CO₂ rather than assuming the bed lacks surface area. Different sulfur species have different absorption and reaction behavior, so packing height, absorbent chemistry, reaction kinetics, temperature, and the analytical acceptance basis should be evaluated separately.
P
Pingxiang Daier Separation TechSep 21, 20264 min read

Engineering Evaluation Case: A Chilled-Solvent VOC Absorber Performs Well at the Top but the Solvent Warms Up Through the Bed

When a chilled-solvent VOC absorber underperforms, evaluate solvent temperature rise through the packed bed, gas sensible heat, heat of absorption, solvent circulation, chiller duty, solvent regeneration, and possible intercooling. Designing the entire bed at the inlet solvent temperature can overestimate the available absorption driving force.
P
Pingxiang Daier Separation TechSep 21, 20264 min read

Engineering Evaluation Case: A Vacuum Degasser Has Enough Packing but Dissolved Oxygen Remains High Because Air Leaks into the System

When a vacuum degasser misses the dissolved-oxygen target despite clean packing, inspect air ingress through manways, flanges, seals, drains, and vacuum equipment. Total pressure alone may not reveal the problem if the vacuum pump compensates for leakage. Oxygen partial pressure, vacuum-system load, liquid distribution, water temperature, and analyzer accuracy should be reviewed together.
P
Pingxiang Daier Separation TechSep 21, 20263 min read

Engineering Evaluation Case: A Wastewater Air Stripper Begins Foaming After Surfactants Enter the Feed

When surfactants enter a wastewater air stripper, stable foam can increase liquid holdup, raise pressure drop, reduce operating range, overload the demister, and disturb mass transfer. Water chemistry, upstream source control, airflow, packing openness, anti-foam effects, and pretreatment should be reviewed before replacing packing or increasing blower capacity.
P
Pingxiang Daier Separation TechSep 21, 20264 min read

Engineering Evaluation Case: The Scrubber Meets the Gas-Removal Target but the Downstream Fan Keeps Corroding

When a scrubber meets its gas-removal target but the downstream fan corrodes, investigate mist carryover, demister velocity, wall bypass, drainage, packing entrainment, downstream condensation, and deposit chemistry. Gas-phase removal efficiency and liquid-droplet control are separate performance requirements.