P
Pingxiang Daier Separation TechSep 15, 20265 min read

 How Ship and Offshore Motion Affects Tower Internals on FPSO and FLNG Units

Ship and offshore motion repeatedly tilts liquid surfaces, redistributes tray and packed-bed flow, changes downcomer seals, creates sloshing loads, and applies cyclic forces to tower internals. Reliable FPSO and FLNG design requires a defined six-degree-of-freedom motion basis, orientation-sensitive hydraulic analysis, adequate distributor head and freeboard, controlled compartmentation, packing restraint, and fatigue-resistant supports. Stationary performance tests alone cannot demonstrate suitability at sea.
P
Pingxiang Daier Separation TechSep 15, 20265 min read

How to Specify Duplex Stainless-Steel Tower Internals and Their Welds

Duplex stainless-steel tower internals obtain their performance from controlled ferrite–austenite balance and freedom from harmful intermetallic phases. Alloy chemistry verified by PMI is not enough. Reliable procurement defines product form, forming limits, filler metal, heat input, interpass temperature, shielding, repair limits, phase-balance verification, corrosion testing where required, surface restoration, and controlled field modification.
P
Pingxiang Daier Separation TechSep 15, 20266 min read

How Gas Binding Causes Maldistribution in Tower Liquid Distributors

Gas binding occurs when entrained, evolved, or displaced gas becomes trapped in distributor headers, laterals, troughs, or submerged inlets. It causes delayed filling, pressure oscillation, intermittent discharge, branch maldistribution, and dynamic loading. Prevention requires mapping true high points, providing safe and cleanable vent paths, controlling feed aeration and flashing, testing from an empty condition, and verifying installed orientation and slope.
P
Pingxiang Daier Separation TechSep 15, 20266 min read

How Vacuum-Truck Cleaning Can Collapse Thin Tower Internals

Vacuum-truck hoses can create concentrated differential pressure or depressurize enclosed internal compartments when a nozzle seals against thin tower components. Prevention requires suitable stand-off nozzles, vacuum relief, verified vent paths, component-specific limits, controlled hose routing, and structural review of corroded internals. Any seal or movement event should trigger inspection because small deformation can impair tray, distributor, demister, or packing performance.
P
Pingxiang Daier Separation TechSep 15, 20266 min read

 How to Plan a Performance-Guarantee Test for New Tower Internals

A tower-internal performance-guarantee test must define measurable criteria, exact operating conditions, stabilization time, instrument accuracy, sampling, balance closure, data reduction, uncertainty, external-equipment boundaries, and retest rules before startup. Commissioning completion is not performance acceptance. Reliable conclusions require synchronized raw data and an agreed stable operating window tied directly to the contractual guarantee.