P
Pingxiang Daier Separation TechSep 15, 20266 min read

How Perforation Pattern and Ligament Width Control Tower-Internal Plate Strength

Tower-internal perforated plates must satisfy hydraulic free-area requirements without losing the ligament network needed for strength and stiffness. Hole size, pitch, pattern, orientation, edge distance, manufacturing tolerance, cutouts, and support locations determine net-section strength, buckling, deflection, and fatigue resistance. Procurement drawings and inspections should specify minimum ligaments and final as-built geometry, not only nominal open area and plate thickness.
P
Pingxiang Daier Separation TechSep 15, 20266 min read

 How to Define Water-Test Acceptance Criteria for Tower Liquid Distributors

Tower-distributor water testing should distinguish dimensional verification from process-performance qualification. Reliable acceptance requires defined operating cases, justified scaling between process liquid and water, low- and high-flow testing, zone-based discharge measurement, liquid-level mapping, realistic supports, calibrated instruments, and complete raw data. Differences in viscosity, surface tension, density, and wetting must be addressed before water results are used to guarantee
P
Pingxiang Daier Separation TechSep 15, 20265 min read

 How to Specify and Verify Tower Internals for Oxygen-Enriched Service

Tower internals for oxygen-enriched service require system-specific ignition assessment, compatible materials, movement-resistant geometry, controlled fabrication, validated cleaning, representative inspection, sealed packaging, and clean installation. Ordinary visual cleanliness or a generic “oxygen compatible” declaration is insufficient. The owner and supplier must define the operating envelope, governing standard, acceptance tests, traceability, and response to any contamination or rework.
P
Pingxiang Daier Separation TechSep 15, 20265 min read

 How to Prevent Polythionic Acid Stress Corrosion Cracking of Stainless Tower Internals

Polythionic acid stress corrosion cracking can attack sensitized austenitic stainless tower internals when sulfide scale encounters oxygen and moisture during shutdown. Prevention requires control of material condition, tensile stress, air ingress, washing chemistry, coverage, drainage, and outage sequence. If protection is lost, targeted surface-crack inspection and system-level assessment are necessary because serious cracking may occur without measurable general corrosion.
P
Pingxiang Daier Separation TechSep 15, 20266 min read

How to Attach Tower Internals to Alloy-Clad or Weld-Overlay Vessel Shells

Tower-internal attachments on clad or weld-overlay shells must perform two functions: transfer loads into the structural base metal and maintain a continuous corrosion-resistant process surface. Reliable details define layer preparation, dissimilar-metal welding, dilution control, barrier restoration, staged inspection, and dimensional tolerances. Clear ownership between the vessel and internal suppliers prevents unsafe field improvisation at this critical interface.